GPS synchronized master clock for NTP network time synchronisation RS232 RS485
GPS synchronised master clock - NTP Time Server network time synchronisation RS232 RS485

4860, 4860net & 4860netclient series Master Clock, GPS Synchronised - NTP Time Server for Network Synchronisation

1974 - 2008
34 years of Master Clock Design and Time Synchronisation

4860, 4860net and 4860netclient series Master Clock

GPS Synchronised - NTP Time Server for Network Time Synchronisation

GPS synchronised master clock - NTP time server for network time synchronisation

The Wharton 4860, 4860net and 4860netclient series of systems GPS synchronized master clock provides a complete precision timing solution for all types of commercial systems, from NTP network time synchronisation, the control and time synchronization of a single piece of intelligent equipment, the synchronization of other large networks and systems incorporating a wide variety of communications, recording, surveillance, information and many types of mechanical and electronic digital and analogue secondary slave clocks.

Each master clock is preprogrammed with a wide range of user selectable time message formats for the time synchronization of many different types and makes of CCTV, voice recording, security and other digital equipment via RS232 and RS485 serial links.

The range is designed for simple installation and 'setup and forget' operation.

features to top of page
Display The 4860 series master clock has a 14mm (0.6”) high, bright red six digit display of time, date or status information which is visible at distances of up to 7m (20ft). The time display can be configured to show either local or UTC time.
NTP and SNTP network time synchronization

net versions operate as a NTP time server on a TCP/IP network, serving NTP/SNTP time-packets directly to clients on the network. Network Time Protocol (NTP) v2, v3 and v4 clients are supported in the unicast mode of operation (RFC1305 & RFC1119). Simple Network Time Protocol (SNTP) v3 and v4 clients are supported in the unicast mode of operation (RFC2030 & RFC1769).

The 4860netclient version allows time synchronization from an NTP time source, enabling the control and synchronisation of large digital clock and other systems across existing structured TCP/IP cabling networks.

Serial ASCII RS232 & RS485 outputs The 4860 and 4860net master clock has a standard user configurable serial ASCII data port with a wide range of data and message formats available at programmable intervals or on request. Master clocks can also be supplied with two or four RS232+RS485 outputs as an extra cost option.
w482® time code output This standard output provides a time code to drive up to 50 400A series clocks, calendar clocks and time-zone clocks displaying time or time and date in up to 15 different global time zones.
1pps output A precision one pulse per second signal of 100mS duration is available at RS232 levels. The leading edge of the signal is within 50uS of UTC when locked to GPS.
Relay output A user configurable voltage-free, change-over relay contact pair rated at 500mA @30v dc is available and may be used to provide status information or a periodic signal at user selectable intervals between every 5 seconds to once per day at a user programmable time.
IRIG timecode output 4861 versions have a 1KHz amplitude modulated 3v p-p, 600 ohm transformer coupled code output user configurable for IRIG-B, Afnor 87-500, NENA 911 or IEEE 1344 formats.
EBU timecode output 4862 versions provide EBU longitudinal time code (LTC) at 2000bps with 25 complete frame messages per second.
Optional impulse outputs The 486x and 486xnet master clock may be supplied with a dual channel 24v impulse output rated at 200mA per channel by specifying the .IMP option. Each output is programmable for one second, half minute or one minute alternate polarity impulses. The fully protected output drive circuits detect overload, short circuit and power failure conditions and automatically corrects resulting time errors on fault removal.
The impulse output option is not available if the the unit is fitted with four serial ports.
Case The 4860 series master clock is housed in 1U high rack mounting cases suitable for either free standing or rack mounting applications.
Power supply The 4860 series master clock will operate from a 100-250v 50/60Hz ac supply. Versions are available to operate from 24v or 48v dc supplies at extra cost. The operational location and local voltage should be specified at time of order to ensure that the unit is supplied with the appropriate mains connection.
 
timekeeping & synchronisation to top of page
486x and 486xnet master clocks will operate either as stand-alone units or synchronised from external time references.
Stand-alone operation When used in stand-alone configuration the clock maintains time keeping from a high stability internal temperature compensated crystal oscillator. The clock is pre-programmed for leap-years and can be user programmed for the required automatic seasonal time-change.
4860 & 4860net
  • DCF & MSF radio time codes (requires 484 series radio time code receiver)
  • GPS satellite time signals (requires 488GPS time synchronisation sub-system)
  • synchronisation to IRIG-B (B123) and afnor NFS 87-500 signals is available to special order and at extra cost.
4860netclient
  • 4860netclient models will synchronise to an NTP time source on a TCP/IP computer network.
 
RS232 & RS485 interfaces to top of page
Each RS232+RS485 serial interface can be configured for many different pre-programmed data message formats for specific CCTV, security and embedded equipment time synchronisation.
Message repetition rates Non-specific message formats are user selectable for transmission every second, every minute, every five minutes, every hour, every day or on request.
Message data rate & format The data rate and format of non-specific messages may be set for 1200, 2400, 4800, 9600 or 19200 baud, 7 or 8 data bits and even, odd or no parity.
Standard message formats The following standard message formats are pre-programmed in the 4860 series master clock in addition to four specific Wharton formats. Where referenced please refer to the appropriate application note. If the data rate, format and repetition rate are pre-defined by the application these parameters are pre-set.

If you have any queries regarding the suitability of the 4860 series of master clocks for your application or have an application not covered by the following list please contact our engineers.

 
  • Adder Digital Technology
  • ADT Site Guard - application note AN132
  • AIT Comfile
  • Ascom NIS2000
  • ASC Telecom DL2 - application note AN129
  • ASC Telecom Marathon - application note AN136
 
  • ATIS MDS2000
  • AudioSoft
  • Baxall DTL 960 - application note AN141
  • BAXNET / Vista - application note AN139
  • Cartner
  • Coe - application note AN120
 
  • Dedicated Micros Digital Sprite, Sprite2, BX2- application note AN127
  • Dedicated Micros Uniplex Series I/II
  • Geutebruck MultiScope
  • Geutebruck TDT-10 / VicroSoft / AMC
  • GPZDA NMEA Message
  • Grosvenor Technology Janus - application note AN132
 
  • Grundig / Plettac Vaz300
  • Harmony - application note AN132
  • Loronix / Verint - application note AN132
  • LUL (Standard / Northern Line formats)
  • Macq Electronic SA
  • Maxpro
 
  • Meyertech Zoneview - application note AN123
  • Mitsubishi HS-S5600 - application note AN112
  • Mitsubishi HS-S8300 - application note AN133
  • Moser-Baer IF482
  • NATS Link Protocol
  • Neal - application note AN124
 
  • NetClock2 - application note AN128
  • Norbain Vista Columbus
  • Panasonic AG6040 / 6730 / 6740 / 6760 - application note AN113
  • Panasonic WJHD500
  • Panasonic WJSX850
  • Petards Cobyt
 
  • Philips/Bosch Allegiant LTC8300, 8511C, 8610/00,8719A, 8810/00, 8910/00 series
  • Philips/Bosch Burle TC8286 & TC8288
  • Philips/Bosch Divar - application note AN140
  • Philips/Bosch DVR1
  • Philips/Bosch LTC2600
  • Philips/Bosch LTC3990/50
 
  • Racal CD20
  • Racal Wordsafe
  • Schauer
  • Scientific Atlanta / CSI - application note AN111
  • Serial reference clock for standard NTP distribution - application note AN128
  • Sony HSR1 / 1P / 2 / 2P - application note AN135
 
  • Syac DigiEye
  • Racal ICR64 & EBCDIC ICR64
  • Racal Wordnet
  • Synectics - application note AN126
  • Tardis
  • Team Simoco
  • Tecton Darlex - application note AN137
 
  • Tecton Drax - application note AN101
  • Tecton Kramplex - application note AN125
  • Tecton Rugby Clock Interface
  • Tower Access Control
  • Ultrak Maxpro - Max1000
  • Vicon Kollector DVR range
  • Vicon ViconNet System
 
  • Vicon VPS - application note AN100
  • Vision Factory Cameo - application note AN117
  • Vision Factory Cameo D1 - application note AN138
  • Vision Factory Montage - application note AN115
  • Vision Factory Montage+ - application note AN116
  • Vision Research Company - Krammer 4 - application note AN102
 
environment to top of page
Power supply  Internal PSU 100-250v 50/60Hz ac. The power consumption is ‹0.4A @230v.
Battery backup › 1 year.
Operating temperature 0-50°C
Relative humidity 0% to 95% non condensing
MTBF ›50,000 hours
Accuracy-basic
  • Stand-alone operation: 0.1 sec/day 0-45°C
  • Synchronised to MSF or DCF: within 30mS of UTC
  • Synchronised to GPS: within 50uS of UTC
Network timing accuracy
-4860net only
Clients typically synchronised within 1-10 mS of the 4860net timebase depending on the network time delay and jitter. (NTP)
EMC 4860 series master clocks, comply with the European Community Electromagnetic Compatibility Directive 89/336/EEC (as amended by 91/263/EEC, 92/31/EEC and 93/68/EEC) and Low Voltage Directive 73/23/EEC (as amended by 93/68/EEC), when installed and used in accordance with our recommendations. They conform to the following international standards:
  • EN 61000-6-1
  • EN 61000-6-3
  • EN 60950
 
order codes to top of page
4860net.S2.EU.IMP
4860 net .S2 .EU .IMP
basic part
number
NTP serial ports power supply
cable code
impulse option
4860 = standard
4861= with IRIG output
4862= with EBU output
none
net
netclient
.S1 = 1 port
.S2 = 2 ports
.S4 = 4 ports
.AU = Australian 240v 50Hz
.EU = European 230v 50hz
.UK = UK style 230v 50Hz
.US = US style 110v 60Hz
add .IMP for dual
impulse channels
(not available on four
serial port versions - ,S4>)
 
system expansion to top of page
484 series MSF and DCF radio time code receivers - high performance omni-directional receivers for protected external mounting:
  • 484.02 MSF receiver
  • 484.03 DCF receiver
Unidirectional receivers with rotating bracket for internal use:
  • 484.06 MSF receiver
  • 484.07 DCF receiver
488BGPS GPS time synchronization sub-system. Comprises active GPS antenna with post mounting bracket, 12 channel receiver/decoder unit and interconnecting cables.
486-08 8 way RS232 buffer unit. Housed in 1U high rack mounting case
4301 bi-directional RS232 to RS485 converter. Mini plastic housing.
 
special designs to top of page
If you have a special master clock or ethernet time synchronization reference requirement that is not covered by our standard range of products please do not hesitate to contact our technical department.
 

Copyright 2008 Wharton Electronics Limited. All Rights Reserved
GPS synchronised master clock - NTP time server for network time synchronisation

Wharton GPS master clocks with NTP Time Synchronisation